Cookie Img
Send Inquiry Send SMS
Mars EDPAL Instruments Pvt. Ltd
Mars EDPAL Instruments Pvt. Ltd  Banner
Home » Products » Spectrum Analyzer 1GHz with Tracking Generator » Laboratory Measuring Instruments » Spectrum Analyzer 1GHz with Tracking Generator

Spectrum Analyzer 1GHz with Tracking Generator

Spectrum Analyzer 1GHz  with Tracking Generator
Spectrum Analyzer 1GHz with Tracking Generator
Send Inquiry
Product Code : ME 5001TG
Product Description

We are a well established supplier of Spectrum Analyzer 1GHz with Tracking Generator to our highly esteemed clients. It is used in scientific industry as per the requirements of varied patrons. We acquire it from our reliable vendors who have been associated with us for years. Tested quality raw material is used in its making along with the help of advanced tools and equipment. Our professionals conduct various inspections to ensure that Spectrum Analyzer 1GHz with Tracking Generator is free from any defects.

Features :

 

  • ME 5001 - Frequency range 150kHz ~1050MHz
  • ME 5001TG - Frequency range 150kHz ~1050MHz (with Tracking Generator)
  • 4.5 Digit display center & marker frequency, 0.1MHz resolution
  • Amplitude range -100dBm ~ +13dBm
  • Filters 20KHz, 250KHz & Video Filter
  • AM/FM Demodulator included
  • Full range built-in Tracking Generator 150kHz ~ 1050MHz
  • Output Power 1dBm to ~ 50dBm (50ohms)

Technical Specifications:

  • Frequency range : 150kHz to 1050MHz (-3dB)
  • Frequency resolution : 100kHz, Display 4 digit
  • Display accuracy center freq. : +100kHz
  • Display accuracy marker : 0.1% Span +100kHz
  • Frequency stability : <150kHz /hr (Drift)
  • Frequency scan width : Zero scan 0Hz/div, and 100kHz in 1-2-5 seq.
  • Frequency scan width accuracy : +10%
  • IF bandwidth (-3dB) : Resolution 20kHz& 250kHz
  • Video bandwidth VBW : 400kHz
  • Sweep time (Fixed) : 23ms

  • Amplitude
  • Amplitude range : 100dBm to +13dBm
  • Screen display range : 80dB (10dB/div)
  • Reference level : -27dBm ~ +13dBm (in 10dB steps)
  • Reference level accuracy : +2dB
  • Average noise level : -103dBm (250kHz RBW)
  • Frequency response : +2dB(Relative to 250MHz, ATTN 10dB)
  • Spurious responses : <-75dBc (2 signals, -27dBm (3rd order)
  • inter modulation each Freq. Distance >3MHz)
  • Harmonic distortion : <-75 dBc (2nd, 3rd)
  • Absolute amplitude accuracy : +2.5dB

Input

  • Input impedance : 50ohms
  • Input connector : BNC
  • Input attenuator : 0 to 40 dB (4 x 10dB steps)
  • Input attenuator accuracy :+2dB / 10dB steps
  • Max input level : +10dBm, (0dB attenuation)
  • : +20dBm (with 20dB attenuation)
  • DC : +25V

Tracking Generator (Available in Model ME 5001TG Only)

  • Output frequency range : 150kHz ~ 1050MHz
  • Output power level : -50dBm , +1dBm (In 10dB steps & fine control)
  • Output attenuator : 0 ~ 40 dB (4 x 10dB steps)
  • Output attenuator accuracy :+1dB
  • Output flatness : +1.5dB (150kHz ~ 1050kHz)
  • spurious outputs
  • Harmonic & non : <20dBc
  • harmonic spurs
  • Output Impedance : 50ohms (BNC female)
Miscellaneous
  • AM/Demodulator : Ear phones, load impedance
  • Included Ear Phones : >8ohms
  • Load Impedance : >8ohms
General
  • Display : CRT 6 inch, 8 x 10div internal Graticule
  • Trace rotation : Adjustable on Front panel
  • Line voltage : 220V +10%, 50 to 60 Hz
  • Power consumption : Approx. 25W
  • Power requirement : 220 VAC +10% , 50 Hz
  • Weight : 7.0Kg Approx.
  • Dimensions (mm) : 280 (L) x390(B) x 130(H)

Standard Accessories :

Power cable, Probe - 2Nos., Ear phone, Instruction manual


Mars EDPAL Instruments Pvt. Ltd.
X


Mars EdPal Instruments Pvt. Ltd. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Ltd.